Calorimetric system for measurement of synchronous machine losses PROJECT TITLE :Calorimetric system for measurement of synchronous machine lossesABSTRACT:An open-cycle air-cooled calorimetric system for the measurement of power losses of a 150-kVA synchronous generator is described. The enthalpy increase and mass flow of the cooling air are determined by measuring the temperature rise, relative humidity, absolute pressure and the pressure drop over a known aerodynamic resistance. The loss measurements are performed using the balance method by calibrating the system against a set of heating resistors. In addition, the difference in heat leakage between the balance test and actual test run is determined by measuring two additional calibration curves. The losses of the test machine are measured in three different loading points. From the error analysis, measurement errors of 5.0 and 1.9% are obtained for the total electromagnetic loss at no load and in rated-load operation, respectively. Did you like this research project? To get this research project Guidelines, Training and Code... Click Here facebook twitter google+ linkedin stumble pinterest Life cycle assessment of a three-phase electrical machine in continuous operation 3D transient temperature field analysis of the stator of a hydro-generator under the sudden short-circuit condition