PROJECT TITLE :

Interruption in Air for Different Medium-Voltage Switching Duties

ABSTRACT:

Air is an environmentally benign various to SF6 for use in medium-voltage load-break switches. A easy, axisymmetric take a look at switch has been used for empirical studies of the thermal section of current interruption in atmospheric air. The aim is to quantify how the pressure drop across the nozzle influences the interrupting capability at a different rate of rise of the recovery voltages (RRRVs) and with different current amplitudes. Tests with pressure drops in the vary 0.one-1.one bar, RRRVs of 40, eighty, and one hundred sixty V/ μs, and currents of three hundred, 60zero, and 900 A were applied. Normally, the present which will be successfully interrupted is proportional with the pressure drop. Likewise, a steeper RRRV needs a proportionally higher pressure drop for the interruption to achieve success. For compact air load-break switches for the important 24 kV/630-A category, it appears sufficient to produce a pressure drop of around 0.twenty five bar lasting for at least twenty ms to go with the “mainly active load” test-sort requirements.


Did you like this research project?

To get this research project Guidelines, Training and Code... Click Here


PROJECT TITLE :Recovery of dielectric strength after DC interruption in vacuumABSTRACT:So as to analyze the influence of the electrode separation, arc time and frequency of the reverse current on the breaking capacity of vacuum
PROJECT TITLE :Effect of high-frequency high-voltage impulse conditioning on inrush current interruption of vacuum interruptersABSTRACT:The objective of this paper is to analyze the impact of a high-frequency high-voltage impulse
PROJECT TITLE:Measurement and stochastic modeling of handover delay and interruption time of smartphone real-time applications on LTE networksABSTRACT:For continuous services of mobile user equipment (UE), Long Term Evolution
PROJECT TITLE :Interruption in Air for Different Medium-Voltage Switching DutiesABSTRACT:Air is an environmentally benign alternative to SF6 for use in medium-voltage load-break switches. A simple, axisymmetric test switch has
PROJECT TITLE : Network Resource Allocation for Users With Multiple Connections Fairness and Stability - 2014 ABSTRACT: This paper studies network resource allocation between users that manage multiple connections, possibly